Leaving VMware Means Leaving vSAN


Your vSAN Exit, Start to Finish
Why Leaving VMware Means Leaving vSAN
The storage layer holding every production VM goes with the hypervisor.
What vSAN Costs You Today
Per-core and per-TiB licensing, plus the CPU and memory vSAN takes from every host.
Where vSAN Data Can Go
The three exit paths open to vSAN customers, and how the alternative compares with vSAN ESA.
Moving Off vSAN, Live
Evacuating vSAN hosts one at a time, then a demonstration from Dave’s lab.
Live demo · Dave VincentWhy a vSAN Exit Is Harder
vSAN Shops Took a Double Hit
Per-Core Subscriptions
Broadcom’s move to per-core subscriptions raised the base cost of every host.
Per-TiB vSAN Capacity
Capacity beyond the bundled entitlement is licensed per TiB, on top of the per-core charge.
VCF to Get the Entitlement
Most vSAN shops end up on VMware Cloud Foundation, paying a premium for features they never planned to use.
Three Realistic Exit Paths
The Bolt-On Problem
- Works only on all-flash, only with compression, scoped to one disk group, where one failed drive takes the disk group offline.
- Runs as a post-process job, so new data consumes full capacity until the job gets to it.
- Reserves extra memory for the storage controller VM, with guidance to limit it to workloads like full-clone VDI.
Buying Storage You Already Own
- Internal capacity is stranded. The drives that held vSAN data stay in the servers, unused.
- Array controllers are servers. A dual-controller array is two x86 servers running the vendor’s storage software.
- Their CPUs sit mostly idle. Controllers use RAM as cache, and applications rarely push the array near its maximum performance.
One Code Base, One Set of Servers
- No infrastructure VMs. Storage and networking are ready the moment VergeOS installs. The first VM you create is yours.
- Shared resources, not contested ones. Storage and virtualization draw from the same pool of CPU and memory instead of competing for it.
- Runs on bare metal you own. Including the hosts vSAN runs on today.
- Day-two simplicity. One interface and one update cycle for compute, storage and networking.
One Interface, Nothing Installed Yet
- Compute, storage and networking in one interface
- Storage and networking ready the moment VergeOS installs
- No management VMs to deploy before the first workload
Dave Vincent · Recorded in the labWhat to Demand From a vSAN Alternative
Runs without VMware
A virtual SAN that runs only under VMware trades one inflation problem for another.
Reuses the vSAN hardware
And lowers RAM, CPU and capacity overhead per host to delay the next purchase.
Matches the vSAN basics
Drive failure protection, snapshots, immutable snapshots and encryption.
Supports more than NVMe
SAS and SATA SSDs and hard drives treated as production storage, not archive.
Global inline deduplication
Data is reduced before it consumes capacity, across every drive in every node.
Migrates VMs and vSAN data
Production keeps running on VMware until a short final cutover.
NVMe-Only vs. Every Tier
An NVMe-only design was an acceptable trade a year ago. With today’s drive prices it looks short-sighted.
Moving a Live SQL Workload Between Tiers
- A SQL Server workload running under load
- Its data moves to a different tier with the VM online
- Performance follows the tier, and the move is reversible in seconds
Dave Vincent · Recorded in the labAfter the Write vs. Before It
The Same Big File, Written Again and Again
- The write counter climbs with every pass
- Deduplication rate before the script runs, and after
- Capacity used barely moves, because the duplicate writes never land
Dave Vincent · Recorded in the labWhat Storage Depends On
Recovering a Virtual Data Center From a Remote Site
- An edge site’s virtual data center replicated to a remote site
- The primary site goes away
- VMs, networks and storage policies come up together at the remote site
Dave Vincent · Recorded in the labRoll Through the Hosts One at a Time
- 1Start. Three ESXi hosts running vSAN. Confirm two can absorb the third.
- 2Free host 3. vMotion its VMs off, evacuate its vSAN data with full data migration, then install VergeOS.
- 3Move host 2’s VMs. IOmigrate backs them up into VergeFS. Test, run an incremental, cut over.
- 4Convert host 2. Install VergeOS. Its drives join VergeFS.
- 5Move host 1’s VMs. Back up, test, incremental, cut over.
- 6Finish. Install VergeOS on host 1. Same servers, same drives, no vSAN.
Migrating VMs Off VMware
- VergeOS connects to vCenter and backs up the VMs
- Copies are tested while production keeps running on VMware
- An incremental update, then a short cutover
Dave Vincent · Recorded in the labTreat the Exit as a Storage Decision
Run on what you own
The right alternative installs on the servers and drives vSAN runs on today, and keeps them in service longer.
Match vSAN, then beat it
Server-side storage with the vSAN basics, plus global inline deduplication and support for every media type.
Keep production running
A backup-style migration moves VMs and data while workloads stay on VMware until cutover.
Map Your vSAN Exit
VMware Exit Assessment
A one-on-one call with George or Dave. We look at your vSAN cluster with you and map out each exit path for your environment, including which servers stay in production and what the migration timeline is.

