Mastering Disaster Requires Better Infrastructure
Disasters come in more than one size. Most leave the building standing and still take out several drives, a rack of servers, or every file share at once. The infrastructure underneath the workloads decides how fast you recover from each one.


Most Disasters Leave the Building Standing
DR plans get written for the lost data center. The events behind most downtime sit in the middle of this scale, and each one still takes dozens of servers and applications offline at once.
Mastering Disaster Requires Better Infrastructure
Recovery speed is set by the platform underneath the workloads. When that platform keeps running past drive and server failures, spots ransomware inside its own storage layer, and moves an entire data center between sites, most disasters end before a restore ever starts.
Multiple Drive and Server Failures
Keep Running Past the Resiliency Factor
RF2 and RF3 keep data online through drive and server failures, and each workload gets its own setting. When failures go past that factor, ioGuardian keeps the virtual machines running and repairs the system, with a recovery point measured in minutes. Workloads on a failed server restart on the surviving nodes with no operator in the loop.
- RF2 and RF3 set per workload, not per array
- ioGuardian engages once RF2 or RF3 is exceeded
- Applications restart on surviving nodes on their own
Two drives fail on two servers, ioGuardian repairs them with the VMs still running, then a whole server drops and its VMs restart on the survivors.
Hardware Failure, Live
Fail Two Drives, Then a Server
Run against a live workload that stays up on screen the whole time.
- Fail two drives and go straight past the resiliency factor.
- ioGuardian holds the data online and repairs the system.
- Kill a server and watch its workloads restart on the survivors.
The workload keeps serving through both drive failures and the server loss. No restore job runs.
Ransomware Recovery
Detect in Minutes, Recover the Whole Data Center
Encryption breaks deduplication. ioFortify watches the deduplication rate inside the storage layer and alerts within 10 to 15 minutes of an attack starting. ioClone snapshots capture the entire virtual data center every 10 to 15 minutes, every VM, volume, and network, and they are immutable, so the attacker cannot change them.
- ioFortify detection built into the storage layer
- Immutable VDC snapshots on a 10 to 15 minute schedule
- Recovery promotes a clean snapshot with no data movement
Deduplication holds near 90 percent until encryption starts. The rate collapses, ioFortify raises the alert, and the VDC rolls back to the last clean snapshot.
Ransomware Recovery, Live
Roll Back an Infected Data Center
The recovery workflow, run start to finish against a virtual data center.
- Mount a pre-attack snapshot in quarantine and scan it.
- Promote the clean copy to production in place.
- Keep the infected copy for forensics.
A clean data center returns from an immutable snapshot, with the infected copy held for forensics.
Lose the Site
DR Moves the Data Center, Networking Included
A virtual data center wraps every VM, volume, and network into one object. ioReplicate sends that object to the DR site asynchronously, deduplicated and WAN-aware, so a failover brings the applications up together with the networks they depend on. Customers report DR tests that finish in under an hour.
- ioReplicate replicates the entire virtual data center
- Networking crosses with the workloads it serves
- The DR site is a running copy you can test any time
The whole VDC replicates to the DR site. When the primary site goes dark, the same VDC comes up at the DR site with its networks intact.
Site Failover, Live
Fail Over the Data Center
The largest disaster on the scale, and the last test of the session.
- Fail over a virtual data center to the second site.
- Applications and their networks arrive together.
- Recover, then fail back, with the workload live throughout.
The virtual data center fails over to the DR site, runs there, then fails back to the primary.
One Platform for Every Size
Better infrastructure changes the answer at every size. Each row runs from the same console on the same code base.
| Single drive failure | No downtime | RF2 or RF3 absorbs it. The application sees nothing. |
| Multiple drive failures | No downtime | ioGuardian keeps data online past RF2 and RF3 and repairs the system. |
| Multiple server failures | Auto restart | Workloads restart on the surviving nodes on their own. |
| Ransomware | Minutes | ioFortify detects the attack, and a clean ioClone snapshot of the whole VDC is promoted in place. |
| Site outage | Failover | ioReplicate fails the entire virtual data center over, networking included. |
Better Infrastructure on the Hardware You Already Own
RF2 and RF3, ioGuardian, immutable snapshots, instant recovery, and DR orchestration are part of VergeOS at no additional software cost. VergeOS runs on the servers already on your floor, including refurbished hardware.